* RECOMMENDED * HPE ESXi Utilities Offline Bundle for VMware vSphere 6.7 By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. Type: | Software - System Management | Version: | 3.2.0(20 Apr 2018) | Operating System(s): | VMware vSphere 6.7 | File name: | esxi6.7-util-bundle-3.2.0-12.zip (10 MB) |
The HPE ESXi Utilities Offline bundle for VMware vSphere 6.7 includes HPONCFG, BOOTCFG, TESTEVENT, CONREP , and SSACLI utilities for configuration of servers. HPONCFG can be used to set up and reconfigure the iLO (Integrated Lights-Out) management controller of a server. BOOTCFG can be used to set up the boot configuration for the server. SSACLI can be used in the configuration of HP Smart Array controllers and attached storage. The TESTEVENT utility generates test WBEM indication and test SNMP trap. The CONREP Utility enables server hardware configuration capture, set and duplication. Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Supports VMware vSphere 6.7 To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value: 3e28617250eaf048679a7fc21af59c02eefb6e4e408bdd777827e86902355c13 | esxi6.7-util-bundle-3.2.0-12.zip |
Reboot Requirement: Reboot is required after installation for updates to take effect and hardware stability to be maintained. Installation:
Installing Offline Bundles on an vSphere 6.7 Host Using vSphere CLI 6.7 esxcli Utility You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes the procedure using offline bundles. Prerequisites Before you can update or patch a vSphere 6.7 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface vSphere 6.7 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the vSphereCLI 6.7. see the VMware vSphere Command-Line Interface Guides. Procedure - Power off any virtual machines that are running on the host and place the host into maintenance mode.
- Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
- Install the bundle on the ESXi host.
- Install remotely from client, with offline bundle contents on a online depot:
esxcli -s -u root -p mypassword software vib install -d - Install remotely from client, with offline bundle on ESXi host:
esxcli -s -u root -p mypassword software vib install -d - Install from ESXi host, with offline bundle on ESXi host:
esxcli software vib install -d
- After the bundle is installed, reboot the ESXi host for the updates to take effect.
- (Optional) Verify that the vibs on the bundle are installed on your ESXi host:
esxcli -s -u root -p mypassword software vib list - (Optional) Remove individual vibs. can be identified by listing the vibs as shown in #5:
esxcli -s -u root -p mypassword software vib remove -n
Installing Offline Bundles on an vSphere 6.7 Host Using VMware vCenter Update Manager The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide. End User License Agreements: HPE Software License Agreement v1 Boost License Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Important:
For additional information about the utilities mentioned in this product, please refer to the document 'HPE VMware Utilities User Guide for VMware vSphere 6.7 for April 2018' which is located at www.hpe.com/info/vmware/proliant-docs. For additional information about the utilities mentioned in this product, please refer to the document 'HPE VMware Utilities User Guide for VMware vSphere 6.7 for April 2018' which is located at www.hpe.com/info/vmware/proliant-docs. Version:10.6.10 (12 Jan 2021) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Includes an updated the HPE Smart Storage Administrator CLI (SSACLI). Version:10.6.0 (5 Oct 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Updated the HPE Smart Storage Administrator CLI (SSACLI) Version:3.5.5 (12 Aug 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Updated the Smart Storage Administrator CLI (SSACLI) Version:3.5.0 (17 Jan 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Updated the Smart Storage Administrator CLI (SSACLI) Version:3.4.5 (16 Sep 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Updated the Smart Storage Administrator CLI (SSACLI) Version:3.4.0 (2 Apr 2019) Version:3.3.0 (27 Jun 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Updated the Smart Storage Array Command Line Interface (SSACLI) utility Version:3.2.0 (20 Apr 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Supports VMware vSphere 6.7 Type: | Software - System Management | Version: | 3.2.0(20 Apr 2018) | Operating System(s): | |
DescriptionThe HPE ESXi Utilities Offline bundle for VMware vSphere 6.7 includes HPONCFG, BOOTCFG, TESTEVENT, CONREP , and SSACLI utilities for configuration of servers. HPONCFG can be used to set up and reconfigure the iLO (Integrated Lights-Out) management controller of a server. BOOTCFG can be used to set up the boot configuration for the server. SSACLI can be used in the configuration of HP Smart Array controllers and attached storage. The TESTEVENT utility generates test WBEM indication and test SNMP trap. The CONREP Utility enables server hardware configuration capture, set and duplication. EnhancementsUpgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Supports VMware vSphere 6.7 Installation InstructionsTo ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value: 3e28617250eaf048679a7fc21af59c02eefb6e4e408bdd777827e86902355c13 | esxi6.7-util-bundle-3.2.0-12.zip |
Reboot Requirement: Reboot is required after installation for updates to take effect and hardware stability to be maintained. Installation:
Installing Offline Bundles on an vSphere 6.7 Host Using vSphere CLI 6.7 esxcli Utility You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes the procedure using offline bundles. Prerequisites Before you can update or patch a vSphere 6.7 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface vSphere 6.7 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the vSphereCLI 6.7. see the VMware vSphere Command-Line Interface Guides. Procedure - Power off any virtual machines that are running on the host and place the host into maintenance mode.
- Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
- Install the bundle on the ESXi host.
- Install remotely from client, with offline bundle contents on a online depot:
esxcli -s -u root -p mypassword software vib install -d - Install remotely from client, with offline bundle on ESXi host:
esxcli -s -u root -p mypassword software vib install -d - Install from ESXi host, with offline bundle on ESXi host:
esxcli software vib install -d
- After the bundle is installed, reboot the ESXi host for the updates to take effect.
- (Optional) Verify that the vibs on the bundle are installed on your ESXi host:
esxcli -s -u root -p mypassword software vib list - (Optional) Remove individual vibs. can be identified by listing the vibs as shown in #5:
esxcli -s -u root -p mypassword software vib remove -n
Installing Offline Bundles on an vSphere 6.7 Host Using VMware vCenter Update Manager The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide. Release NotesEnd User License Agreements: HPE Software License Agreement v1 Boost License Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Important:
For additional information about the utilities mentioned in this product, please refer to the document 'HPE VMware Utilities User Guide for VMware vSphere 6.7 for April 2018' which is located at www.hpe.com/info/vmware/proliant-docs. ImportantFor additional information about the utilities mentioned in this product, please refer to the document 'HPE VMware Utilities User Guide for VMware vSphere 6.7 for April 2018' which is located at www.hpe.com/info/vmware/proliant-docs. Revision HistoryVersion:10.6.10 (12 Jan 2021) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Includes an updated the HPE Smart Storage Administrator CLI (SSACLI). Version:10.6.0 (5 Oct 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Updated the HPE Smart Storage Administrator CLI (SSACLI) Version:3.5.5 (12 Aug 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Updated the Smart Storage Administrator CLI (SSACLI) Version:3.5.0 (17 Jan 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Updated the Smart Storage Administrator CLI (SSACLI) Version:3.4.5 (16 Sep 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Updated the Smart Storage Administrator CLI (SSACLI) Version:3.4.0 (2 Apr 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Updated the Smart Storage Administrator CLI (SSACLI) Version:3.3.0 (27 Jun 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Split screen v3 3 3. Updated the Smart Storage Array Command Line Interface (SSACLI) utility Version:3.2.0 (20 Apr 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Supports VMware vSphere 6.7 |
|
- Feb 19, 2013 The HP Array Configuration Utility is a web-based application that helps you configure HP ProLiant SMART-2 Array Controllers, HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers.
- SMART Utility 3.2.6 is Out! SMART Utility 3.2.6 has been released, which adds full support for Catalina. NOTE: This is the last free version. Version 4.0 will be out soon, and will be a paid upgrade, unless you purchased after May 1st, 2016 and then it is free.
An inline three-cylinder engine is essentially a straight six engine lopped in half. Normally in a straight six, the two outer cylinders reach top dead centre (TDC) in unison, with the other four.
Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models. |
|
Smart Utility 3 2 5 Cylinder Number
Features
PassMark DiskCheckup™ allows the user to monitor the SMART attributes of a particular hard disk drive. SMART (Self-Monitoring Analysis and Reporting Technology) is a feature on a computer's hard disk for providing various monitoring indicators of disk reliability. If SMART is enabled on a hard disk, the system administrator can receive analytical information from the hard drive to determine a possible future failure of the hard drive.
SMART monitors elements of possible long term drive failure, such as 'Spin Up Time', the number of start/stops, the number of hours powered on and the hard disk temperature.
3 To The Negative 2 Power
DiskCheckup displays the current values of the SMART attributes, along with the Threshold value for that attribute. If an attribute drops below its threshold, the drive cannot guarantee that it will be able to meet its specifications in the future.
Note that SMART attributes change slowly over time and are helpful attempts to diagnose the life span of a particular drive. DiskCheckup monitors these changes over a long period and predict the date (if available) of the Threshold Exceed Condition (TEC), which is displayed on the main window.
Smart Utility 3 2 5 Cylinder Diesel Engine
DiskCheckup can also execute built-in Disk Self Test (DST) routines implemented by the vendor to detect drive failures. There are two main self test routines: Short Test and Extended Test. The results of these tests are displayed in DiskCheckup.
DiskCheckup has the ability to detect and set the sizes of the Host Protected Area (HPA) and Device Configuration Overlay (DCO). The HPA/DCO are hidden areas of the hard disk that contain data not accessible by the user. These areas can be removed to reveal the data hidden within these areas.
DiskCheckup also displays device information, such as the drive geometry, serial number, model number, media rotation rate, and supported features. The real-time activity of the disk is also displayed and updated periodically.